Goceng Medical Support Customize EMS Facial Electrodes

August 13 , 2025

EMS facial electrode is mainly used for electrical stimulation beauty of facial muscles and is commonly found in microcurrent beauty devices, lifting and firming devices, etc 

 

The functions of the EMS facial electrode

 

1. Conducting EMS microcurrent :   Through the electrode sheet, the low-frequency or medium-frequency current output by the instrument is transmitted to the skin and muscles, stimulating the contraction of facial expression muscles. • Helps improve muscle relaxation and promote blood circulation.

2. Stable skin contact :  The soft electrode sheet conforms to the facial curve, reducing air gaps and avoiding a stinging sensation.

3. Enhance user comfort :  Keep the skin moist to prevent discomfort caused by direct dry current stimulation.

4. Precise stimulation :  Training is targeted at specific muscle groups (such as the zygomatic, maxillary, and orbicularis oculi muscles) based on the shape and position of the electrodes.

 

The function of Hydrogel in the EMS face electrode 

 

Conductive medium: containing water and electrolytes, it can efficiently transmit electrical signals. 

Skin cushioning: Soft and skin-friendly, reducing the stinging sensation caused by electrical current stimulation.

Adhesion and fixation: Helps the electrode sheet firmly adhere to the skin surface and is less likely to slip off. 

Moisturizing effect: It keeps the skin moist when used for a long time, preventing dryness or allergies. 

Replaceable: After a certain number of uses, the hydrogel will dry out and lose its viscosity, and needs to be replaced.

 

 

 

The function of Silver Conductive Paste

 

Silver paste is a highly Conductive material printed on the conductive layer of the electrode pad : 

• Excellent electrical conductivity: silver has a low resistivity (about 1.59×10⁻⁸ Ω·m), which can ensure the stable transmission of EMS signals.

• Evenly distribute the current: Evenly disperse the current throughout the adhesive layer to prevent burns or discomfort caused by local hot spots.

• Anti-oxidation: The surface of silver paste is resistant to corrosion, which extends the service life of the electrode.

• Reduce signal loss: Ensure that the output electrical stimulation intensity is consistent with the set value.

 

The combination of the adhesive layer and the silver paste

 

1. The silver paste layer is responsible for efficiently transmitting current to the electrode surface.

2. The gel layer (hydrogel) serves as a conductive medium, gently and evenly transmitting the current to the skin.

 

 

Precautions for Use

 

Keep the skin clean and avoid oil and cosmetics affecting conductivity.

Replace the hydrogel after it dries, otherwise the current will become stronger or uneven.

The facial skin is relatively thin, so it is recommended to use it at a low current for a short time.

Do not let the silver paste layer come into direct contact with the skin to prevent allergic reactions

 

Choosing Goceng's hydrogel can guarantee :

 

Stable current transmission ,

High stimulation comfort ,

Longer electrode life.